OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN TECHNICAL DATA
Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster Page 24 of 27
) +41 1 940 20 06 2 +41 1 940 22 14 8 http://www.weiss.ch * [email protected]
Overall Gain CH2 Control Change 1011 cccc $47 (cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0 - 127
Thresholds CH1
Control Change
1011 cccc
$48..$4B
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0 - 127
Thresholds CH2
Control Change
1011 cccc
$4C..$4F
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0 - 127
MSC Mode
Control Change
1011 cccc
$50
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
Bit 0: on/off, 1=on
Bit 1: Input: 1=MSC, 0=L/R
Bit 2: EQ: 1=MSC, 0=L/R
Bit 3: Output: 1=MSC, 0=L/R
Bit 4: 1 = CH swap, 0= norm
CH1 / 2 SELECT Control Change 1011 cccc $51 (cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0, 1
Set Ganged Mode
Control Change
1011 cccc
$52
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0, 1
Toggle A <> B
Control Change
1011 cccc
$53
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0, 1
EQ Bypass
Control Change
1011 cccc
$54
(cccc) Channel No.
0vvv vvvv (vvvvvvv) New Value:
0, 1
System Reset
1111 1111
-
Recall Snapshot 0 to WS A